Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (2024)

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (1)

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (2)

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (3)

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (4)

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (5)

  • Tool.com /
  • Measuring Tools /
  • Gas Monitor /
  • Fixed Gas Monitor /
  • Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL

0 review(s) | Add your review

The newly available discount fixed oxygen (O2) gas monitor covers two detection ranges of 0 to 25% VOL and 0 to 30% VOL, which is suitable for a variety of industrial application scenarios. Equipped with high brightness Nixie tube display, it supports 4-20mA and RS485 signal output, providing clear and intuitive data presentation and reliable remote communication.

SKU: GD300-O2

*
*
*
*
*

$434.77

i h

Free shipping

Delivery date: 6-12 days

  • Overview
  • Reviews

Overview

Fixed oxygen gas detectors for sale are designed for high accuracy and reliability, suitable for oxygen concentration detection from 0 to 25% VOL or 0 to 30% VOL optional. Utilizing advanced electrochemical sensing technology, the unit is capable of providing accurate readings in as little as 10 seconds, with an accuracy of ±3% F.S. and a resolution of 0.01. Supporting a variety of mounting options, the unit enhances safety and efficiency for users.

Specification

ModelGD300-O2
Detection PrincipleElectrochemistry
GasOxygen (O2)
Range (Optional)0~30% Vol, 0~25% Vol
Resolution0.01%Vol
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional) Note4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionG1/2 is the inlet and outlet for power and signal lines
Pipe-mounted type: The installation thread size of the instrument is M45*P2.0
Operating Time24h
Explosion-proof GradeEx d llC T6
Protection GradeIP65
CertificationCE, ATEX
Working Voltage12~36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
AccessoriesPower adapter: Input 100-240VAC 50/60Hz, Output 24VDC 2A (Optional USA plug & Europe plug)


Fixed Gas Monitor User Manual

  • Fixed Gas Monitor User Manual.pdf
  • Protocol of RS485 for Fixed Gas Monitor.pdf
  • Calibration Procedures of Fixed Type Gas Monitor.pdf

Gas Monitor Functions

  • This oxygen gas detector adopts three-wire 4-20mA analog signal output, relay output, RS485 output (optional).
  • The original imported sensors, with a unique infrared remote control function, non-contact operation and maintenance of hydrogen gas tester.
  • Compatible with a variety of control alarms, PLC, DCS and other control systems, you can realize remote monitoring, gas monitoring is more accurate and reliable.
  • Explosion-proof design grade is ExdlCT6, fast, credible and more stable.
  • Full software auto-calibration function with temperature compensation can perfectly realize the compensation of gas concentration under different temperature environment.

Fixed O2 Gas Monitor Details

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (6)

Fixed Oxygen Gas Monitor with Alarm Dimension (Unit: mm)

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (7)

Tips: How to choose a suitable fixed oxygen gas monitor?

When selecting a stationary oxygen gas monitor, you need to consider the monitoring range, sensor type, response time, protection level and installation environment. Make sure the gas detector meets the required detection accuracy and response time, and has sufficient protection level (e.g. IP65 or higher) to adapt to the harsh environment. Choose an oxygen detector with reliable data transmission and alarm functions for safety. Certifications such as CE, ATEX, etc. are also important.

Related products

Fixed Hydrogen (H2) Gas Tester, 0 to 2000/5000/9999 ppm

GD300-H2

High quality hydrogen gas tester for sale, advanced equipment that can cover the detection range of 0 to 2000/5000/9999 ppm hydrogen, providing high and low alarm selectable relay outputs, equipped with audible and visual alarms to ensure timely warning in case of abnormal gas concentration, suitable for a wide range of industrial applications.

$634.77

Fixed Hydrogen Sulfide (H2S) Gas Monitor, 0 to 20/50/100/200 ppm

GD300-H2S

This fixed hydrogen sulfide gas monitor adopts advanced electrochemical detection principle, accurately detects H2S concentration in the range of 0 to 20/50/100/200ppm with a resolution of up to 0.01ppm. It supports 4-20mA and RS485 signal outputs, which is flexibly applicable to different monitoring systems.

$486.77

Fixed Chlorine (CL2) Gas Monitor, 0 to 10/20/50/100 ppm

GD300-CL2

High performance sensor chlorine gas monitor, measuring range 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm, accurate and reliable measurement, the output signal can be selected from 4-20mA and RS485. hold high/low alarm settings, provide 1NO+1NC or 2NO+2NC relay output, to ensure the real-time monitoring and safety response.

$585.59

Fixed Carbon Monoxide (CO) Gas Tester, 0 to 500/1000/2000 ppm

GD300-CO

Fixed carbon monoxide gas tester with display. Gas monitor adopts high quality sensor and advanced microprocessor technology, can detect 500/1000/2000 ppm, with data display, fast response, high accuracy, good stability. 12-36V DC power supply, standard with 4-20mA and RS485 optional output. Explosion-proof design, suitable for a variety of harsh environments.

$486.77

Fixed Oxygen (O2) Gas Monitor, 0 to 25% VOL, 0-30% VOL (2024)

FAQs

What is a normal oxygen level on a gas monitor? ›

OXYGEN GAS SENSOR ALARMS

Normal oxygen levels range between 19.5% and 23% (normal 20.8%). Serious health effects, fires or death by asphyxiation can occur quickly when oxygen levels are unsafe (below 16% or above 21%).

What does O2 mean on a gas monitor? ›

Accurate oxygen (O2) measurements are essential to prevent injuries or deaths in situations with potentially high or low levels of oxygen. O2 gas detectors will typically trigger an alarm when the oxygen level drops below 19.5 percent volume.

What is a fixed oxygen Analyser used to measure? ›

An oxygen analyzer is used to measure trace or percent levels of oxygen concentration in gas streams or the surrounding atmosphere.

What is the gas alarm for low oxygen percentage? ›

Oxygen deficiency monitors will go into alarm mode at readings below 19.5%. This enables audible/visual alarms to indicate to personnel that an action needs to be taken prior to injury. Humans will not detect ill effects for short duration exposures until oxygen levels reach 14-16 %, but caution is required.

What is a dangerously low oxygen level? ›

People should contact a health care provider if their oxygen saturation readings drop below 92%, as it may be a sign of hypoxia, a condition in which not enough oxygen reaches the body's tissues. If blood oxygen saturation levels fall to 88% or lower, seek immediate medical attention, says Dr. Lutchmansingh.

What is the normal oxygen level by age? ›

Blood Oxygen Levels by Age Using a Pulse Oximetry Chart
ConditionsBy AgeSpO2
NormalAdults & Children95% to 100%
Normal>70 years oldabout 95%
Brain is affectedAdults & Children80% to 85%
CyanosisAdults & ChildrenBelow 67%
Dec 21, 2022

What is the typical measuring range for an oxygen analyser? ›

4) What is the typical measuring range for an Oxygen Analyser? The analyzer is capable of measuring from zero to 100% oxygen in the gas phase.

What is the reading of the oxygen analyzer? ›

Table 1 Pulse oximeter readings chart
Oxygen saturation (Sp02%)Pulse rate (Beats per minute)Reading
95%–100%60–100Normal
95%101–109Continue monitoring
93%–94%110–130See your health care provider
92% or lower131 or higherGo to the emergency room or call 911
Jun 24, 2024

How to measure oxygen gas? ›

Ultrasonic oxygen sensors use sound speed to measure the amount of oxygen in a gas or liquid sample. In liquid, upstream and downstream sensors measure the velocity difference between high-frequency sound waves. The change in velocity is proportional to the amount of oxygen in the sample.

What are the safe levels for gas monitor? ›

Do not allow the instrument to draw liquid through the tube and into the meter. 7. Readings must be above 19.5% O2 and below 23.5% O2, 10% LEL, 25 ppm CO, and 10 ppm H2S for legal entry into a space.

What is the normal range for oxygen gas? ›

For most people, a normal pulse oximeter reading for your oxygen saturation level is between 95% and 100%. If you have a lung disease such as COPD or pneumonia, your normal oxygen saturation level may be lower. Your healthcare provider will let you know what levels are acceptable.

What is the normal range of the oxygen sensor? ›

A properly functioning oxygen sensor will show a rapidly fluctuating output voltage between approximately 0.1 and 1.0 volts. The time taken for the voltage to change from 0.1 V to 1.0 V (referred to as the lean to rich response time) should be about 300 milliseconds.

What is the normal range for oxygen blood gas test? ›

Normal Results

Values at sea level: Partial pressure of oxygen (PaO2): 75 to 100 millimeters of mercury (mm Hg), or 10.5 to 13.5 kilopascal (kPa) Partial pressure of carbon dioxide (PaCO2): 38 to 42 mm Hg (5.1 to 5.6 kPa) Arterial blood pH: 7.38 to 7.42.

Is 92 a good oxygen level? ›

Low oxygen level, also called hypoxemia, is considered a reading between 90% and 92%. A reading this low means you might need supplemental oxygen or that there may be challenges that affect how your lungs function. A result below 90% indicates that you should seek medical attention.

References

Top Articles
Latest Posts
Article information

Author: Dean Jakubowski Ret

Last Updated:

Views: 5900

Rating: 5 / 5 (70 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Dean Jakubowski Ret

Birthday: 1996-05-10

Address: Apt. 425 4346 Santiago Islands, Shariside, AK 38830-1874

Phone: +96313309894162

Job: Legacy Sales Designer

Hobby: Baseball, Wood carving, Candle making, Jigsaw puzzles, Lacemaking, Parkour, Drawing

Introduction: My name is Dean Jakubowski Ret, I am a enthusiastic, friendly, homely, handsome, zealous, brainy, elegant person who loves writing and wants to share my knowledge and understanding with you.